Search results for "Diode-pumped solid-state laser"
showing 6 items of 6 documents
Cavity Ring-Down Spectroscopy measurements of Acetone concentration
2017
This research has been partly supported by the National Research Programme "The next generation of information and communication technologies" (NexIT).
Observability of the Risken–Nummedal–Graham–Haken instability in Nd:YAG lasers
2003
Multilongitudinal mode instability in ring Nd:YAG lasers is theoretically analyzed. After we review the way in which the standard two-level laser theory applies to this laser we extend the theoretical treatment to include transverse effects. We do this by taking into account the finite transverse section of the active medium and by assuming a Gaussian transverse distribution for the intracavity field. Finally we demonstrate that multimode emission develops whenever the intracavity field waist diameter is almost equal to the active rod diameter. We conclude that continuous-wave diode-pumped Nd:YAG lasers with low cavity losses are good candidates for the observation of the Risken–Nummedal–Gr…
Characteristics of laser operation at 1064 nm in Nd:YVO_4 under diode pumping at 808 and 914 nm
2011
International audience; A comparative study between 808 and 914nm pumping of Nd:YVO4 crystals for laser operation at 1064nm has been carried out. Using similar setups, performances of both configurations were first studied in the continuous wave, small-signal gain, and Q-switched regimes. Thanks to a numerical model, it is shown that fluorescence quenching and upconversion processes limit the possible uses for the 914nm pumping scheme to regimes with low population inversions
Efficient pulsed 946-nm laser emission from Nd:YAG pumped by a titanium-doped sapphire laser
2008
Efficient pulsed room-temperature laser emission at 946 nm is obtained from a Nd:YAG rod pumped by a Ti-doped sapphire laser in the free-running mode. Three bonded YAG rods of 3-mm diameter with different Nd concentrations and active lengths were tested. A maximum output energy of 83.5 mJ at 3 Hz was obtained with a slope efficiency of 32.3% in an end-pumping configuration.
Diode-pumped bulk Er:Yb:Glass 1.54μm pulsed laser with 1.2J output and 25% optical efficiency
2002
We report a pulsed transversely diode-pumped compact Er:Yb:Glass laser of uncomplicated design, delivering output energy of approx. 1.2J in free-running operation and 25% optical slope efficiency.
Short-wavelength soft-x-ray laser pumped in double-pulse single-beam non-normal incidence
2010
We demonstrated a $7.36$ nm Ni-like samarium soft-x-ray laser, pumped by $36$ J of a neodymium:glass chirped-pulse amplification laser. Double-pulse single-beam non-normal-incidence pumping was applied for efficient soft-x-ray laser generation. In this case, the applied technique included a single-optic focusing geometry for large beam diameters, a single-pass grating compressor, traveling-wave tuning capability, and an optimized high-energy laser double pulse. This scheme has the potential for even shorter-wavelength soft-x-ray laser pumping.